Single Stage Packaged Geothermal Heat Pump
Installation & Operating Instructions
Model: (RA-VE*)
Application
Forced air Geo source installation
Equipped for optional AUX EL strip heat (controller included)
Dual Heat – combine this geothermal unit with standby gas or oil furnace
LMC (Load management control) ready
Tested to UL Standards 1995 and CSA Standards C22.2
Domestic Water Heater, Desuperheater
Energy Star promotes the desuperheater and it is standard with
this series. However, it only efficiently produces hot water if
the tank temperature is less than 115° F (46° C). A hot water
buffer tank is suggested for proper and efficient application,
see page 16.
Note
The EZGEO control board has a configuration mode dial
switch. This must be correctly set during installation, see
EZGEO Controller (HC112) and Field Setup sections.
HP-Y2 indicator light is not used on this model.
Drawings:
HC112, NH401, NR402, UAW503, UAW506, NG0001
DO NOT DESTROY THIS MANUAL. PLEASE READ CAREFULLY AND KEEP IN A SAFE
PLACE FOR FUTURE REFERENCE BY A SERVICE TECHNICIAN.
Northern Geo LLC
75 West Veum
Appleton, MN 56208
320-297-9100
www.northernheatpump.com [email protected]
Vue de la page 0
1 2 3 4 5 6 ... 55 56

Résumé du contenu

Page 1 - Model: (RA-VE*)

09/11/2014 NI401 Single Stage Packaged Geothermal Heat Pump Installation & Operating Instructions Model: (RA-VE*) Application  Forced air

Page 2 - Table of Contents

09/11/2014 8 NI401 Figure 3 P/T Adapter Mechanical Installation Source Water WARNING LOOP DESIGN IS EXTREMELY IMPORTANT FOR PROPER HEAT PU

Page 3 - Safety Considerations

09/11/2014 9 NI401 Figure 4 – Pressurized Closed Loop with Flow Center – Typical piping arrangement. Figure 5 – Non-Pressurized Closed Loop wit

Page 4 - 09/11/2014 2 NI401

09/11/2014 10 NI401 To Earth Loop From Earth Loop From Flush Cart To Flush Cart Step 3 From Heat Pump To Heat Pump Step 5 To Flush Cart From Flus

Page 5 - PRESSURE DROP MULTIPLIERS

09/11/2014 11 NI401 versus the pressure drop table (Table#3) and determine the actual flow rate. If the flow rate is low, recheck the selection of

Page 6 - 4.4 31.1 36.2 50

09/11/2014 12 NI401 Open Loop Well to Well – An open system gets its name from the open discharge of water after it has been used by the heat pump.

Page 7 - Product Dimensions

09/11/2014 13 NI401 Figure 6: Open Loop Well to Well – Typical piping diagram. Open Loop Freeze Protection Switch – Heat pump installations on op

Page 8

09/11/2014 14 NI401 Converting to Right Hand Return One of the unique features of your NorthStar Series Heat Pump is the ability to quickly and eas

Page 9

09/11/2014 15 NI401 Built-in Electric Strip Heat (AUX EL) Electric Resistance Heat (optional) –NHP NorthStar Series heat pumps may be ordered with

Page 10 - P/T Adapter

09/11/2014 16 NI401 Desuperheater, Domestic Hot Water General NHP NorthStar Series units are equipped with a desuperheater and an integr

Page 11

09/11/2014 17 NI401 Figure 7 – Desuperheater Piping, Buffer Tank This arrangement is the most effective and efficient and the recommende

Page 12

09/11/2014 NI401 Table of Contents Introduction 1 Product Configurator (NC028) 2 Mechanical Specifications 3 Electrical Data 4 Product Dimens

Page 13 - Antifreeze

09/11/2014 18 NI401 Preventive Maintenance Air Filter Maintenance – The air filter in your Northern Heat Pump is designed for optimum performance

Page 14

09/11/2014 19 NI401 Condensate Drain In the cooling season, condensation is collected in a

Page 15

09/11/2014 20 NI401 Electrical Hookup WARNING DISCONNECT ALL ELECTRICAL POWER BEFORE ELECTRICALLY CONNECTING OR SERVICING THE UNIT. FAIL

Page 16

09/11/2014 21 NI401 EZGEO Controller EZGEO Features Review attached HC112 HELPS document which lists the various characteristics and capa

Page 17

09/11/2014 22 NI401 Utility Load Control Bottom 2-screw terminal block marked blue and blu/wht. Remove the jumper and extend the two wires to the ut

Page 18

09/11/2014 23 NI401 Visual example only – the exact connections will depend upon operating mode. Review previous section – EZGEO Co

Page 19

09/11/2014 24 NI401 Temperature Sensors WARNING BOTH MUST BE INSTALLED ON ALL MODELS. Duct Sensor (ST) – install in the Geo supply ai

Page 20 - Preventive Maintenance

09/11/2014 25 NI401 Additional Hookup or Special System Equipment Concerns Additional Room Thermostat Connection Points On the EZGEO board, upp

Page 21 - Condensate Drain

09/11/2014 26 NI401 Field Setup Overview Your EZGEO-equipped Northern Heat Pump can be set up at your location to fit most any requirements and

Page 22 - Electrical Hookup

09/11/2014 27 NI401 Switchover Temperature (SW OVER) This switch is shipped from the factory with a square “GAS” label. This label should be removed

Page 23 - EZGEO Controller

09/11/2014 1 NI401 Introduction When used and controlled properly, geothermal heat pumps can save hundreds of dollars in heating and cooling costs

Page 24

09/11/2014 28 NI401 Gas Furnace CFM See previous page on gas furnace hookup for proper programming of ECM motor for the required CFM output. Outdoo

Page 25

09/11/2014 29 NI401 Undersized geothermal heat pump with fossil fuel furnace. • Mode Dial: C • SW Over Dial: 1=-15°F/ 2=-10°F/ 3=0°F/ 4=5°F/ 5=10°

Page 26

09/11/2014 30 NI401 Override Switch – the front panel slide switch (very similar to standard Electro-Mate DFC) is a direct hardware

Page 27

09/11/2014 31 NI401 Power On, Startup Before applying power to the heat pump, check the following items: 1. Water supply plumbing to the heat pu

Page 28 - Field Setup Overview

09/11/2014 32 NI401 Operational Tips ICM Board – The ICM board performs the functions controlling the compressor operation: system lo

Page 29

09/11/2014 33 NI401 Unit Operating Conditions – Heat ModelSource TempSource temp ΔGPM Air temp Δ Amps 240Blower AMPSCFMDischarge pressure at 68 deg

Page 30

09/11/2014 34 NI401 Unit Operating Conditions – Cool ModelSource TempSource temp ∆GPMAir temp Δ Dry bulbAmps 240Blower AMPSNominal CFMDischarge pre

Page 31 - Operation Indicators

09/11/2014 35 NI401 Troubleshooting – EZGEO Control Sensor Temperature Calibration – both remote sensors are digital electronic and fact

Page 32

09/11/2014 36 NI401 Troubleshooting/Repair Helps 1. This EZGEO controller contains several interference suppression components, but as a

Page 33 - Power On, Startup

09/11/2014 37 NI401 EZGEO Bypass Behind the front panel hinged door the various wires from the EZGEO board terminate on a Geo stand

Page 34 - Operational Tips

09/11/2014 2 NI401

Page 35 - 09/11/2014 33 NI401

09/11/2014 38 NI401 Compressor bypass – initial installation or special requirement to heat with AUX EL only. Special configuration, mode B and SW

Page 36 - 09/11/2014 34 NI401

09/11/2014 39 NI401 Accessories/Options Part Number NHP GEO Alarm R-AL-FD-1 Fuse – source loop pump, 10A UFUSE1799 Fuse – desuperheater pump, 3

Page 37

09/11/2014 40 NI401

Page 38

09/11/2014 41 NI401

Page 39

09/11/2014 42 NI401

Page 45 - 09/11/2014 43 NI401

09/11/2014 3 NI401 Mechanical Specifications – R410A Single Stage Compressor MODEL RA-VE-041 (3 ton) RA-VE-053 (4 ton) RA-VE-061 (5 ton) Coax &

Page 53 - 09/11/2014 51 NI401

09/11/2014 4 NI401 Electrical Data – Single Phase Model Voltage Compressor Blower Desup. Pump Loop Pump (Ext) Total Min. Max. Fuse/ HACR (60 Hz) RL

Page 54 - 09/11/2014 52 NI401

09/11/2014 5 NI401 Product Dimensions

Page 55 - 09/11/2014 53 NI401

09/11/2014 6 NI401 Installation Requirements 1. All installation work must be performed by trained, qualified contractors or technician

Page 56 - 09/11/2014 54 NI401

09/11/2014 7 NI401 Figure 1 Horizontal Closed Loop Mechanical Installation Overview This NorthStar Series unit cannot correct airflow problems inhe