09/11/2014 26 NI401
Field Setup Overview
Your EZGEO-equipped Northern Heat Pump can be set up at your location to fit most any requirements and
conditions. This is accomplished with the use of the various dials and switches located on the EZGEO board. It
is extremely important the installer properly goes through this section and sets up the various switches to match
the installation. Again, refer to HC112 Helps EZGEO Controller section for further details on these setups.
The diagram below shows the dial locations on the EZGEO board.
Warning: Power-down reset required whenever changing any of the switch positions on the back side
of the board.
Mode Dial
Mode
Switch
Mode SW OVER Configuration
A Geo only N/A
No AUX EL, no gas, no auto SB, but load control can interrupt
compressor for cooling (not heating)
B
Geo/AUX EL 0
AUX EL (with compressor supplement or emergency), utility
load control, etc.
Geo/AUX EL/gas Value
AUX EL, gas, auto SB, utility load control, etc. AUX EL is
used above SW OVER value, below SW OVER point gas has
priority.
C Geo/gas Value No AUX EL, gas furnace, auto SB, utility load control
D Split/gas Value Not applicable for this model
*Mode B also requires the proper setting and interpretation of SW OVER dial switch. As shown in the mode
selection table, if the configuration is AUX electric only, SW OVER switch must be in position 0. If it is both
AUX EL and gas, the SW OVER switch must be in a temperature value position.